Field Service Ver2.0 Aug.2005
Step
4
Checking of the ISW conditions.
From the Web screen, you can check the current processing condition to see if there is any error.
• "ISW is downloading"
• "ISW is writing"
• "Finish"
• "ISW was canceled due to transferring problem"
• "ISW was canceled due to transferring overtime"
• "ISW was canceled due to writing problem to flash memory"
5
When the ISW is completed successfully, the main body restarts automatically to complete the ISW.
6
After restart of the main body, check the firmware version in "Internet ISW main screen" to see if it is
being updated successfully.
5.3.5

Internet ISW using the mail remote notification system

When the customer engineer sends a mail that describes the key word briefly to the main body, the main body
that receives that mail can download the program from the program server to conduct the rewrite automatically.
For the operating environment and initial setting, see "4.4 Mail remote notification system."
(1) Usage of the Internet ISW using the mail remote notification system
For a command that is sent to the main body and its options, see the table given below.
Command
ISW
I0, I1, I2, I3, I4, I5
C0, C1, C2, C3, C4
F1
N1
P1
5 (minimum)
1440 (maximum)
ISWHELP
Not specified
Note
• The command option for FS-509 and FS-604 is N1.
The type of FS that is connected to the main body is automatically recognized for a suitable firm-
ware to be downloaded from the program server.
Option
Specifies a board that execute ISW.
I: Overall control board (OACB)
C: Printer control board (PRCB)
F: DF control board (DFCB)
N: FS control board (FSCB)
P: IC board (ICB)
It is also possible to specify "= firmware file name" after an optional
name to ISW a specific file in the program server.
Example: ISW I0=56gfi0100000.bin
Specify the time of validity of the mail. (Unit: in minutes) When no
specification is made, 90 minutes are employed.
When the time period after CE sends out a mail until the main body
receive the mail exceeds the time specified here, ISW is not con-
ducted.
Example: ISW I0 5
A help mail that describes the usage of the commands above is
returned.