Field Service Ver2.0 Aug.2005
[2]
[3]
[1]
[3]
[6]
[4]
[1]
[5]
[4]
57gaf2c058na
[2]
[4]
[5]
57gaf2c059na
7.
Remove the C-clip [1], pull out the shaft [2] in the
arrow-marked direction [3] and remove the 3
drum claws [4].
8.
Remove the springs [5], 1 each, from each drum
claws.
Note
• When installing it, be sure to clean the shaft
[1] with a drum cleaner and a cleaning pad.
Installing the drum claw without removing
toner results in a dull operation.
• When installing the drum claw[2], be sure to
take note of the direction of the spring [3].
• When installing the C-clip [4], be sure to
insert it between the ribs [5].
• After installing the drum claw, be sure to
check to see if each drum claw moves
smoothly.
• Make sure the hook section [6] of the spring
comes outside of the rib.
9.
Reinstall the above parts following the removal
steps in reverse.
3. PERIODIC CHECK
47