Field Service Ver2.0 Aug.2005
10.9.4
Install date
Set the starting date of the total counter that is displayed on the utility mode.
When setting the DIPSW 16-4 to 1, the starting date of the total counter is not displayed.
A. Procedure
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [System Input] key.
3.
A sub menu appears on the right side of the screen.
Press the [Install Date] key on the sub menu.
4.
"Setting date input screen"
Enter the new date through the numeric keys.
5.
Press the [OK] key to update data.
Press the [Cancel] key to cancel the setting you updated.
10.9.5
Size setting (Tray 4)
Set the paper size for LU.
Setting DIPSW21-1 to 1 allows the tray 4 size setting in the utility mode.
A. Procedure
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [System Input] key.
3.
A sub menu appears on the right side of the screen.
Press the [Size Setting (Tray4)] key on the sub menu.
4.
"Size setting screen"
Press one of the [Standard Size], [Custom Size], [Wide Size Paper] and [Tab Paper] keys.
5.
"Each of size setting screen"
[Standard Size] :
Select the paper size you want to use.
[Custom Size] :
Set the paper size and select the image position (lead edge, rear edge, center).
[Wide Size Paper] : After selecting the standard size, press the [Input Size] key to set the paper size, and then
select the image position (lead edge, rear edge, center).
[Tab Paper] :
After selecting the standard size, press the [Input Size] key to set the paper size, and then
press the [Number of Tabs] key to set the number of tabs.
6.
Press the [OK] key.
10. TECH. REP. MODE
391