Field Service Ver2.0 Aug.2005
10.5.2

Counter/Data

It is possible to confirm various data held in the machine.
The counter/data also can be checked through the CS Remote Care, list output and the mail remote notification
system.
• Paper Size Counter (Total)
• Paper Size Counter (Copy)
• Paper Size Counter (Print)
• Large Size Counter
• ADF Counter
• Coverage Data History
• Coverage Data List
*1
When setting DIPSW 30-1 to 1, these data can be confirmed.
A. Procedure
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [Counter] key.
3.
A sub menu appears on the right side of the screen.
Press the [Counter/Data] key on the sub menu.
4.
"Collecting data menu screen"
Press the counter item key you want to confirm.
5.
"Collecting data screen"
Press the [Next] or [Back] key to scroll the screen.
Note
• The [Count Reset] key is shown in the individual data confirmation screen of the [Paper Jam
Sectional Counter] and the [Failure sectional counter].
When pressing the [Count Reset] key, "Count reset confirmation screen" is shown, and when
pressing the [Yes] key, the section data is reset. Pressing the [No] key returns to "Individual data
confirmation screen" with the interval data not reset.
Reset these data when you visit the customer of the PM implementation etc. to confirm the jam
or SC occurrence count after it was visited last time.
• Paper Jam History*1
• Jam Counter*1
• Copy Mode Counter*1
• Paper SC History*1
• Service Call Counter*1
• Paper Jam Sectional Counter*1
• Failure Sectional Counter*1
10. TECH. REP. MODE