10. TECH. REP. MODE
10.5.3
Preset parts life counter (parts life counter)
When a part is replaced, reset the counter of the part that has been replaced to manage the service history.
A. Procedure
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [Counter] key.
3.
A sub menu appears on the right side of the screen.
Press the [Parts Life Counter] key on the sub menu.
4.
"Copy count of part menu screen"
Press the [Preset Parts Life Counter] key.
5.
"Copy counter of special parts screen"
Press the [Next] or [Previous] key to scroll the screen.
6.
Press the [↑] or [↓] key to select an item you want to reset.
7.
Press the [Count Reset] key.
8.
"Reset confirm screen"
Press the [Yes] key to reset the counter.
Press the [No] key not to reset the counter. You return to the "Copy counter of special parts screen."
330
Field Service Ver2.0 Aug.2005