Field Service Ver2.0 Aug.2005
10.11.4 Detailed setup procedure
A. I/O check mode, data collection clear valid
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [System Input] key.
3.
"Sub menu screen"
Press the [Software Switch Setting] key.
4.
"Software switch setting mode screen"
Set "03" with the DIPSW number.
Set "6" with the DIPSW bit number.
5.
Set the bit data to "On (1)".
On (1): I/O check mode, data collection clear enabled
Off (0): I/O check mode, data collection clear disabled (default)
6.
Press the [Return] key to finish the configuration.
B. CS Remote Care memory initialization
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [Machine Status] key.
3.
"Sub menu screen"
Press the [I/O Check] key.
4.
"I/O check mode screen"
Enter "15" with the numeric keys. Confirm that "15-00" is displayed on the message display area.
5.
Press the [Access] button.
6.
Enter "98" with the numeric keys.
7.
Press the [Start] button.
Confirm that the output check display switches to "FIN."
C. CS Remote Care function ON
1.
Enter the Tech. Rep. mode.
2.
"Tech. Rep. mode menu screen"
Press the [System Input] key.
3.
"Sub menu screen"
Press the [Software Switch Setting] key.
4.
"Software switch setting mode screen"
Set "15" with the DIPSW number.
Set "5" with the DIPSW bit number.
5.
Set the bit data to "On (1)".
On (1): CS Remote Care function enabled
Off (0): CS Remote Care function disabled (default)
6.
Press the [Return] key to finish the configuration.
10. TECH. REP. MODE