3. PERIODIC CHECK
[5][6]
[4]
[2]
[1]
[1]
[4]
128
[2]
[3]
57gaf2c234na
[2]
[3]
57gaf2c235na
Field Service Ver2.0 Aug.2005
8.
Remove 2 connectors [1].
9.
Remove the 3 screws [2] and then remove the
ADU reverse motor assembly [3] and the belt [4].
Note
• When installing the ADU reverse motor
assembly [3], be sure to set the positioning
hole [5] to the projection [6] of the ADU.
10.
Remove the E-ring [1] and then remove the
spacer [2].
11.
Remove the pulley [3] and pull out the pin [4] from
the shaft.