Konica Minolta bizhub PRO 920 Service Manual page 119

Main body
Hide thumbs Also See for bizhub PRO 920:
Table of Contents

Advertisement

Field Service Ver2.0 Aug.2005
[2]
[3]
[1]
[2]
[2]
[6]
[1]
[2]
[4]
[5]
[6]
57gaf2c119na
[3]
[7]
[5]
[4]
[1]
57gaf2c120na
[3]
57gaf2c121na
8.
Remove the paper feed reference actuator /Fr [1].
9.
Remove the 2 C-clips [2] and then remove the
connecting bearing /Fr [3].
10.
Slide the connecting bearing /Rr [4] in the arrow-
marked direction [5] and remove the mounting
bracket [6].
11.
Remove the pick-up roller [1].
12.
Remove the C-clip [2] and then remove the paper
feed roller [3].
Note
• When installing the pick-up roller [1], be sure
to install it so that the projection [4] comes to
the opposite side of the gear [5].
• When installing the feed roller [3], be sure to
install it so that the flange [6] of the collar
comes to the opposite side of the gear [7].
13.
Release the stopper [2] of the collar [1] and
remove the collar from the pick-up roller [3].
Note
• When installing the pick-up roller, be sure to
check to see if the roller is smeared with
grease.
3. PERIODIC CHECK
87