Relevance To Service Mode; Steps To E-Rds Settings - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

2

Relevance to service mode

E-RDS settings
Item
Script format
0: Disable/ 1:Enable e-Maintenance/ imageWARE Remote
E-RDS
2 bytes
system to send device information, counter data, error
statuses to the UGW.
Default value is 0 (not in use)
URL of UGW (default) :
RGW-ADR
129 bytes
https://a01.ugwdevice.net/ugw/agentif010
(SJIS not
allowed)
The UGW Port Number by default : 443
RGW-PORT
4 bytes
Validation: 1~ 65,535
Perform Communication test with UGW and set "OK!"/
COM-TEST
"NG!" as the result.
COM-LOG
Detailed communication log displays the last 5 error
information, consisting of data, error code, and error
reasons up to now
Max 30 latest loggings retained
Max 128 characters for Error information.
CLEAR
Reset E-RDS settings
SERVICE CALL BUTTON settings
Item
Script format
SCALL-SW
0: Disable (Service Call button is not appeared)/ 1: Enable (
The button is displayed)
Default value is 0 (not in use)
SERVICE BROWSER settings
Item
Script format
Activate Service Browsing.
BRWS-ACT
Browsing info is sent to UGW when OFF (BRWS-ACT=0) is
changed to ACTIVE.
Setting result is displayed as OK! / NG!
Activate Service Browsing.
BRWS-STS
2 bytes
(COPIER > DISPLAY
Browsing info is sent to UGW when OFF (BRWS-ACT=0) is
> USER)
changed to ACTIVE.
Setting result is displayed as OK! / NG!
2
Description
T-2-83
T-2-83
Description
T-2-84
T-2-84
Description
T-2-85
T-2-85

Steps to E-RDS settings

a. Select Servicemode MODE LIST > COPIER > Function > Clear > ERDS-DAT, and then
touch [OK].
* When [MODE LIST] is chosen, an operation guide will be displayed if the item set as the
object of operation is selected and then a green [i] button located in the buttom of screen is
touched. In case of [MODE LIST CLASSIC], this button is not appeared.
[Service Browser] will be appeared after [BRWS-ACT] is set as Active (="1"), and after turning
the power of the device Off/ On. (Default is off.)
b. Select Service mode > COPIER > Function > INSTALL > E-RDS, enter [1] and touch [OK].
This turns ON the function enabling the communication with the UGW.
2-156
F-2-246
F-2-246
F-2-247
F-2-247
2-156

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents