CCD
COPIER>ADJUST>CCD
W-PLT-X
Whiteleveldata(X)entryofwhiteplate
Lv.1
Details
WhenreplacingtheReaderControllerPCB/clearingRAMdata,
enterthevalueofservicelabel.WhenreplacingtheCopyboard
Glass, enter the value of barcode label which is affixed on the
glass.
•
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
•
WhenreplacingtheCopyboardGlass
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
7500to9999
Unit
-
Appropriatetargetvalue
-
Defaultvalue
8271
Requiredtime
-
Relatedservicemode
COPIER.>ADJUST>CCD>W-PLT-Y,W-PLT-Z,BW-TGT
Relatedusermode
-
Supplement/memo
-
W-PLT-Y
Whiteleveldata(Y)entryofwhiteplate
Lv.1
Details
WhenreplacingtheReaderControllerPCB/clearingRAMdata,
enterthevalueofservicelabel.WhenreplacingtheCopyboard
Glass, enter the value of barcode label which is affixed on the
glass.
•
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
•
WhenreplacingtheCopyboardGlass
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
7500to9999
Unit
-
Appropriatetargetvalue
-
Defaultvalue
8735
Requiredtime
-
Relatedservicemode
COPIER.>ADJUST>CCD>W-PLT-X,W-PLT-Z,BW-TGT
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>CCD
W-PLT-Z
Whiteleveldata(Z)entryofwhiteplate
Lv.1
Details
WhenreplacingtheReaderControllerPCB/clearingRAMdata,
enterthevalueofservicelabel.WhenreplacingtheCopyboard
Glass, enter the value of barcode label which is affixed on the
glass.
•
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
•
WhenreplacingtheCopyboardGlass
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
7500to9999
Unit
-
Appropriatetargetvalue
-
Defaultvalue
9418
Requiredtime
-
Relatedservicemode
COPIER.>ADJUST>CCD>W-PLT-X,W-PLT-Y,BW-TGT
Relatedusermode
-
Supplement/memo
-
SH-TRGT
ShadingtgtVL(B&W)[bookmode]:D-Reader
Lv.1
Details
TosettheB&Wshadingtargetvalueincopyboardreading
mode.
•
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
•
WhenreplacingtheScannerUnit
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
1to2047
Unit
-
Appropriatetargetvalue
-
Defaultvalue
1126
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-157