COPIER>OPTION>IMG-FIX
TMP-TB10
Fixingcontroltemperaturesetting:coat2
Lv.1
Details
To set the offset of fixing control temperature for coated paper2
(164to209g/m2).
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Increase the value when fixing failure occurs.
Decrease the value, when fixing offset occurs.
Usecase
When offset/fixing failure occurs on coated paper 2
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-10degC,-1:-5degC,0:0degC,1:+5degC,2:+10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
FXS-TMP7
SettingofITOPcontroltemp:plainppr2
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforplainpaper2(82
to105g/m2).
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeonplainpaper2
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-10degC,-1:-5degC,0:0degC,1:5degC,2:10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8
8
COPIER>OPTION>IMG-FIX
FXS-TMP8
SettingofITOPcontroltemp:transp
Lv.1
Details
TosettheoffsetofITOPcontroltemperaturefortransparency.
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeontransparency
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-10degC,-1:-5degC,0:0degC,1:5degC,2:10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
FXS-TM10
SettingofITOPcontroltemp:coat2
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforcoatedpaper2
(164to209g/m2).
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeoncoatedpaper2
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-10degC,-1:-5degC,0:0degC,1:5degC,2:10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8-325
8-325