COPIER>FUNCTION>MISC-R

CLM-TGT

FineadjustmentofcolorMTFvalue
Lv.1
Details
To perform the filter processing inside of the Reader Controller
sothattheMTFvaluemeasuredbyCLM-PLTN/CLM-DF1/CLM-
DF2becomes55%orlowerofthevalue.
When 1 is specified, the MTF correction filter is calculated again,
andtheMTFvaluebecomes50%orlowerofthevalue(the
image becomes foggy). The backed up MTF filter correction
coefficient is updated.
Usecase
WhendecreasingtheMTFvalue(tomaketheimagefoggy)
uponuser'srequest(moire,incorrectjudgment)
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
0to1
0:55%
1:50%(Theimagebecomesfoggy.)
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
Approx.2minutes
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
TheMTFvalueissetto65%atthetimeofshipment.

BWM-TGT

FineadjustmentofB&WMTFvalue
Lv.1
Details
To perform the filter processing inside of the Reader Controller
sothattheMTFvaluemeasuredbyBWM-PLTN/BWM-DF1/
BWM-DF2becomes55%orlowerofthevalue.
When 1 is specified, the MTF correction filter is calculated again,
andtheMTFvaluebecomes50%orlowerofthevalue(the
image becomes foggy). The backed up MTF filter correction
coefficient is updated.
Usecase
WhendecreasingtheMTFvalue(tomaketheimagefoggy)
uponuser'srequest(moire,incorrectjudgment)
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
0to1
0:55%
1:50%(Theimagebecomesfoggy.)
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
Approx.2minutes
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
TheMTFvalueissetto65%atthetimeofshipment.
8

8

COPIER>FUNCTION>MISC-R

SCANLMP2

Light-upcheckofLEDLampUnit:back
Lv.1
Details
TolightuptheLEDLampUnitforbackside,whichisplaced
intheADF,andcheckwhetherthereisamissingblockorno
lightinginLED.
Usecase
WhenreplacingtheLEDLampUnitforbackside
Adj/set/operatemethod
Selecttheitem,andthenpressOKkey.
Caution
-
Display/adj/setrange
During operation: ACTIVE, When operation finished normally:
OK!
Unit
-
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
Approx.5seconds
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-262
T-8-44
8-262

Hide quick links: