COPIER>ADJUST>HV-TR
2TR-R22
SectrnsATVCcrrnt:normhmdyrcycl2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
recycledpaperatsecondarytransferATVCcontrol(innormal
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N22
Relatedusermode
-
Supplement/memo
-
2TR-R13
SectrnsATVCcrrnt:highhmdyrcycl1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
recycledpaperatsecondarytransferATVCcontrol(inhigh
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N13
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>HV-TR
2TR-R23
SectrnsATVCcrrnt:highhmdyrcycl2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
recycledpaperatsecondarytransferATVCcontrol(inhigh
humidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N23
Relatedusermode
-
Supplement/memo
-
2TR-HN1
SectrnsATVCcrrnt:lowhmdyhvypln1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
relativelyheavyplainpaperatsecondarytransferATVCcontrol
(inlowhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N1
Relatedusermode
-
Supplement/memo
-
8-214
8-214