COPIER>ADJUST>HV-TR
1TR-TGC
AdjofprmrytrnsATVCCtargetcurrent
Lv.2
Details
ToadjusttheoffsetofthetargetcurrentforCuponprimary
transferATVCcontrol.
Asthevalueisincrementedby1,theoffsetisincreasedby2uA.
Increasethevalueifspottymarkormottledimageoccurs.
Decreasethevalueifwhitespotsoccur.
Usecase
Whenanimagefailureduetotheprimarytransferoccurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-50to50
Unit
1uA
Appropriatetargetvalue
-10to10
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
1TR-TGK1
PrmrytrnsATVCBktargetcurrent(clr)
Lv.2
Details
ToadjusttheoffsetofthetargetcurrentforBkuponprimary
transferATVCcontrolinfullcolormode.
Asthevalueisincrementedby1,theoffsetisincreasedby2uA.
Increasethevalueifspottymarkormottledimageoccurs.
Decreasethevalueifwhitespotsoccur.
Usecase
Whenanimagefailureduetotheprimarytransferoccurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-50to50
Unit
1uA
Appropriatetargetvalue
-10to10
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>HV-TR
2TR-N1
SectrnsATVCtgtcrrnt:lowhmdypln1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideofplain
paperatsecondarytransferATVCcontrol(inlowhumidity,600
dpi).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
2TR-N2
SectrnsATVCtgtcrrnt:lowhmdypln2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
plainpaperatsecondarytransferATVCcontrol(inlowhumidity,
600dpi).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-204