COPIER>ADJUST>CCD
DFCH-G2
ComplexchartNo.2data(G)[Backside]
Lv.1
Details
Toderivethefront/backsidelinearity,settheGreendata(for
paperback)ofNo.2imageinDADFcomplexchart.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
1to2550
Unit
-
Appropriatetargetvalue
-
Defaultvalue
2000
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>CCD>DFCH-R10,DFCH-B2,DFCH-B10,
DFCH-G2,DFCH-G10
COPIER>FUNCTION>CCD>DF-LNR
Relatedusermode
-
Supplement/memo
-
DFCH-G10
ComplexchartNo.10data(G)[Backside]
Lv.1
Details
Toderivethefront/backsidelinearity,settheGreendata(for
paperback)ofNo.10imageinDADFcomplexchart.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to2550
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>CCD>DFCH-R2,DFCH-B2,DFCH-B10,
DFCH-G2,DFCH-G10
COPIER>FUNCTION>CCD>DF-LNR
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>CCD
MTF2-M10
MTFvalue10setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to85
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF2-M11
MTFvalue11setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to85
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF2-M12
MTFvalue12setting:horzscan[Front]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to85
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
8-169
8-169