COPIER>DISPLAY>HT-C

DLTA-C-C

DisofARCDATscreenCC-densitydiffer
Lv.2
Details
TodisplaythedifferencebetweentheC-patchtargetvalueand
thecurrentvalueofscreenCinARCDATcontrol.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resetthe
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
DLTA-C-K
DisofARCDATscreenCBk-densitydiffer
Lv.2
Details
TodisplaythedifferencebetweentheBk-patchtargetvalueand
thecurrentvalueofscreenCinARCDATcontrol.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resetthe
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>DISPLAY>HT-C

TGT-A-Y2

ARCDATscrnAY-clrtargetVL(1/2SPD)
Lv.2
Details
TodisplaytheY-patchtargetvalueofscreenAinARCDAT
controlat1/2speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

TGT-A-M2

ARCDATscrnAM-clrtargetVL(1/2SPD)
Lv.2
Details
TodisplaytheM-patchtargetvalueofscreenAinARCDAT
controlat1/2speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

TGT-A-C2

ARCDATscrnAC-clrtargetVL(1/2SPD)
Lv.2
Details
TodisplaytheC-patchtargetvalueofscreenAinARCDAT
controlat1/2speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-