COPIER>DISPLAY>HT-C

SUM-A-C3

ARCDATscrnAC-clrctrldiffer(1/3SPD)
Lv.2
Details
TodisplayC-patchcontroldifferenceofscreenAinARCDAT
controlat1/3speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resettarget
value).Ifnotcorrected,checkPatchSensororreplacethe
developer.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

SUM-A-K3

ARCDATscrnABk-clrctrldiffer(1/3SPD)
Lv.2
Details
TodisplayBk-patchcontroldifferenceofscreenAinARCDAT
controlat1/3speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resettarget
value).Ifnotcorrected,checkPatchSensororreplacethe
developer.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>DISPLAY>HT-C

SUM-B-Y3

ARCDATscrnBY-clrctrldiffer(1/3SPD)
Lv.2
Details
TodisplayY-patchcontroldifferenceofscreenBinARCDAT
controlat1/3speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resettarget
value).Ifnotcorrected,checkPatchSensororreplacethe
developer.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

SUM-B-M3

ARCDATscrnBM-clrctrldiffer(1/3SPD)
Lv.2
Details
TodisplayM-patchcontroldifferenceofscreenBinARCDAT
controlat1/3speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resettarget
value).Ifnotcorrected,checkPatchSensororreplacethe
developer.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-121