Hv-Pri Table; Dis-Tgy; Dis-Tgc; Dis-Tgk - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

HV-PRI
COPIER>ADJUST>HV-PRI

DIS-TGY

DischgcrrntctrlYtgtcrrntadj:1/1SPD
Lv.2
Details
ToadjusttheoffsetoftheYtargetcurrentatdischargecurrent
controlinplainpaper(1/1speed).
Usecase
Whenaimagefailure(sand-likeimage)occurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
5uA
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
DIS-TGM
DischgcrrntctrlMtgtcrrntadj:1/1SPD
Lv.2
Details
ToadjusttheoffsetoftheMtargetcurrentatdischargecurrent
controlinplainpaper(1/1speed).
Usecase
Whenaimagefailure(sand-likeimage)occurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
5uA
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>ADJUST>HV-PRI

DIS-TGC

DischgcrrntctrlCtgtcrrntadj:1/1SPD
Lv.2
Details
ToadjusttheoffsetoftheCtargetcurrentatdischargecurrent
controlinplainpaper(1/1speed).
Usecase
Whenaimagefailure(sand-likeimage)occurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
5uA
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

DIS-TGK

DischgcrrntctrlBktgtcrrntadj:1/1SPD
Lv.2
Details
ToadjusttheoffsetoftheBktargetcurrentatdischargecurrent
controlinplainpaper(1/1speed).
Usecase
Whenaimagefailure(sand-likeimage)occurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
5uA
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-