COPIER>ADJUST>CCD
MTF-M8
MTFvalue8setting:horzscan[Back]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF-M9
MTFvalue9setting:horzscan[Back]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF-S1
MTFvalue1setting:vertscan[Back]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>CCD
MTF-S2
MTFvalue2setting:vertscan[Back]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF-S3
MTFvalue3setting:vertscan[Back]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
MTF-S4
MTFvalue4setting:vertscan[Back]
Lv.1
Details
Setting value for MTF filter coefficient calculation.
EnterthevalueofservicelabelontheReader.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemai)npowerswitch.
Caution
-
Display/adj/setrange
20to80
Unit
-
Appropriatetargetvalue
-
Defaultvalue
50
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>CCD>MTF-CLC
Relatedusermode
-
Supplement/memo
-
8-166