COPIER>ADJUST>MISC
ACS-CNT
SetjdgmtpixelcountareainACS:front
Lv.2
Details
Tosettheareawhichcountsthepixeltojudgethecolor
presenceinACSmode.
Asthegreatervalueisset,thejudgmentareaiswidened.
Usecase
Whenadjustingtheareawhichcountsthepixeltojudgethe
colorpresenceinACSmode
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-2to2
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
ACS-EN2
SetACSmodejdgmtareainDADFmode
Lv.2
Details
TosetthejudgmentareainACSmodeatDADFreading.
Asthegreatervalueisset,thejudgmentareaiswidened.
Usecase
WhenadjustingthejudgmentareainACSmodeatDADF
reading
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-2to2
Unit
-
Appropriatetargetvalue
-
Defaultvalue
1
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>MISC
ACS-CNT2
SetACSjdgmtpixelcountareainDADF
Lv.2
Details
Tosettheareawhichcountsthepixeltojudgethecolor
presenceinACSmodeatDADFreading.
Asthegreatervalueisset,thejudgmentareaiswiden.
Usecase
Whenadjustingtheareawhichcountsthepixeltojudgethe
colorpresenceinACSmodeatDADFreading
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-2to2
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
REOS-PG
SetReosprocessingcoeffctat1200dpi
Lv.2
Details
To set an optimal Reos processing coefficient for 1200dpi print.
PrintPGofthetype55inCOPIER>TEST>PG>TYPE,check
theimagesinthe4areasofthisPG,andspecifythenumber
oftheareainwhichthecharacterproportionandlinewidth
becomeoptimumbytheReosprocessingmoduleinthecaseof
PDL1200dpisetting.
Afterthesettingisdone,outputtheverticalandhorizontal
patternswith3dotsand10spaces,whicharethesameasthe
PG above, in 1200 dpi, and confirm that the result is the same
as the specified area.
Usecase
-
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to4
Unit
-
Appropriatetargetvalue
-
Defaultvalue
2
Requiredtime
-
Relatedservicemode
COPIER>TEST>PG>TYPE
Relatedusermode
-
Supplement/memo
-
8-227