COPIER>ADJUST>HV-TR
2TR-O13
SectrnsATVCtgtcrrnt:highhmdytransp
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthetransparencyat
secondarytransferATVCcontrol(inhighhumidity).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
2TR-HN2
SectrnsATVCcrrnt:lowhmdyhvypln2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
relativelyheavyplainpaperatsecondarytransferATVCcontrol
(inlowhumidity).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N2
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>ADJUST>HV-TR
1TR-TGKT
PrytrnsATVCBktgtcrrntadj:Bkonly
Lv.1
Details
ToadjusttheoffsetofprimarytransferATVCcontroltarget
currentinB&Wmode.
Asthevalueisincrementedby1,theoffsetchangesby1uA.
Ifthevalueistoolarge,foggingetc.duetotransfermemory
occursandifitistoosmall,transferfailureetc.occurs.
Usecase
WhentheimagefailureduetoprimarytransferoccursinB&W
mode
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)ExecutetheprimarytransferATVC(open/closetheFront
Coveretc.)
Caution
-
Display/adj/setrange
-50to50
Unit
1uA
Appropriatetargetvalue
-10to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>1TR-TGY,1TR-TGM,1TR-TGC,
1TR-TGK
Relatedusermode
-
Supplement/memo
-
2TR-T1
SectrnsATVCcrrnt:lowhmdythin1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideofthin
paperatsecondarytransferATVCcontrol(inlowhumidity).
Ifthevalueistoolarge,densitylossduetoexcessivetransferor
high-voltagemottledimageetc.occursandifitistoosmall,burst
imageormottledimageetc.occurs.
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
Increase/decreasethevalueby1whilecheckingthesymptom
eachtime.
Display/adj/setrange
-128to127
Unit
1uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-TR>2TR-N1
Relatedusermode
-
Supplement/memo
-
8-211
8-211