SORTER>ADJUST
SDL-ALM
Setsddlfullstackalarmmode:Fin-C1
Lv.1
Details
Set1whendisablingthestackfullalarmforsaddlestitching.
Usecase
Whendisablingthestackfullalarmforsaddlestitching
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
0to1
0:OFF,1:ON
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
SFT-AMT1
AdjshftamntofShftRoll(frt):Fin-A1
Lv.1
Details
ToadjustthefrontshiftamountoftheShiftRoller.
Asthevalueisincrementedby1,theShiftRollermovestoward
theguideby0.1mm.
Usecase
Whenthefrontshiftamountofthepaperisinappropriate
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
0to50
Unit
0.1mm
Appropriatetargetvalue
0
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
SFT-AMT2
AdjshftamntofShftRoll(Rear):Fin-A1
Lv.1
Details
ToadjusttherearshiftamountoftheShiftRoller.
Asthevalueisincrementedby1,theShiftRollermovestoward
theguideby0.1mm.
Usecase
Whentherearshiftamountofthepaperisinappropriate
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
-50to50
Unit
0.1mm
Appropriatetargetvalue
0
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8
8
SORTER>ADJUST
STP-NTN
AdjofStapleNeedlepitch(A4):Fin-A1
Lv.1
Details
Toadjustthepitchbetweenneedlesfor2-pointstapling.
Asthevalueisincrementedby1,thepitchbetweenneedles
becomeswiderby0.27mm.
Usecase
Whenthepitchbetweenneedlesfor2-pointstaplingis
inappropriate
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
-8to8
Unit
0.27mm
Appropriatetargetvalue
0
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
INSTP-F1
Adjoffrontstapleposition:Fin-A1
Lv.1
Details
Toadjustthepaperpull-inamountoftheGripperatthetimeof
front1-pointstapling.
Asthevalueisincrementedby1,thepaperpull-inamountis
increasedby0.1mm.
Usecase
Whenmisalignmentoccursatthefrontstapleposition
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
-50to50
Unit
0.27mm
Appropriatetargetvalue
0
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-431
8-431