Exp-Led Table; Pr-Exp-Y; Pr-Exp-M; Sh-Adj2 - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

COPIER>ADJUST>MISC

SH-ADJ2

Sharpnesssettingchangefunction
Lv.1
Details
Toadjustthesharpnessofimagesonthesecondsideofa
document,whichissetintheusermode,inthe1-pathduplex
streamreadingmode.
Asthegreatervalueisset,theimagegetssharper.
Ifthevalueistoolarge,moireislikelytooccurinanoutput
imageofCOPYandSEND.
Tomatchtheimagequalitywiththatofthesecondsideinthe
1-pathduplexstreamreadingmode,decreasethevaluewhen
moire on the first side is stronger than the second side, and
increasethevaluewhenitisweaker.
Usecase
WhenmoirefrequentlyoccursonimagesofCOPYandSEND
output
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-3to3
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>MISC>SH-ADJ
Relatedusermode
Settings/Registration>Adjustment/Maintenance>AdjustImage
Quality>Sharpness
Supplement/memo
-
8

T-8-33
8

EXP-LED
COPIER>ADJUST>EXP-LED

PR-EXP-Y

SettingofYPre-exposureLEDcurrent
Lv.2
Details
TosetthecurrentofYPre-exposureLED.
Increasethevaluewhentakingameasurefordrumghost.
Decreasethevaluewhenpotentialisnotappliedwell.
Usecase
When drum ghost is significant (drum pitch is not correct)
Whenpotentialisnotappliedwell
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
0to15
Unit
1/16%
Appropriatetargetvalue
10to15
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

PR-EXP-M

SettingofMPre-exposureLEDcurrent
Lv.2
Details
TosetthecurrentofMPre-exposureLED.
Increasethevaluewhentakingameasurefordrumghost.
Decreasethevaluewhenpotentialisnotappliedwell.
Usecase
When drum ghost is significant (drum pitch is not correct)
Whenpotentialisnotappliedwell
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Donotusethisatthenormalservice.
Display/adj/setrange
0to15
Unit
1/16%
Appropriatetargetvalue
10to15
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-230