COPIER>ADJUST>HV-PRI

OFSTAC-Y

AdjofYclrchargeACcurrent:1/1SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforY.
Asthevalueisincrementedby1,thecurrentvalueisincreased
by20uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Ifthevalueistoolarge,thelifeofthePhotosensitiveDrum
becomesshorter.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
1minute
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTAC-M,OFSTAC-C,
OFSTAC-K
Relatedusermode
-
Supplement/memo
-

OFSTAC-M

AdjofMclrchargeACcurrent:1/1SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforM.
Asthevalueisincrementedby1,thecurrentvalueisincreased
by20uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Ifthevalueistoolarge,thelifeofthePhotosensitiveDrum
becomesshorter.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
1minute
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTAC-Y,OFSTAC-C,
OFSTAC-K
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>ADJUST>HV-PRI

OFSTAC-C

AdjofCclrchargeACcurrent:1/1SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforC.
Asthevalueisincrementedby1,thecurrentvalueisincreased
by20uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Ifthevalueistoolarge,thelifeofthePhotosensitiveDrum
becomesshorter.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
1minute
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTAC-Y,OFSTAC-M,
OFSTAC-K
Relatedusermode
-
Supplement/memo
-