Canon imageRUNNER ADVANCE C5045 Series Service Manual page 432

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

Ecode Detail
Location
Item
Code
E602
0913
00
Title
ErrorinHDD
Description WriteAbort
Remedy
Thedocumentdata(suchasBOXontheHDD)canbe
damaged.
1.EntertheapplicableCHK-TYPE=3inthepartitionto
performHDD-CHECK(duration:severalminutestoseveral
dozensofminutes),andthenturnOFFandthenONthe
power.
2.Iftheabovemeasuresdonotsolvetheproblem,enterthe
applicableCHK-TYPE=3inthepartitiontoexecuteHDD-
CLEAR,andthenturnOFFandthenONtheMainPower
Switch.
(UseSSTtoperformreformat/reinstallationinthecaseof
thefollowing:BOOTDEV,BOOTDEV2andAPL_SEND)
3.Iftherestillremainstheproblem,itcanbecausedby
failurewiththeHDD;therefore,replacetheHDDand
reinstallthesystem.
E602
0914
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
0921
00
Title
ErrorinHDD
Description FailureinHDDconnection
Remedy
ThisistheerrorwhichusuallydoesnotoccurinRead/Write
level.
1.Checkthecableandpowerconnector.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
0922
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
7

Description
7

Ecode Detail
Location
Item
Code
E602
0923
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
0924
00
Title
ErrorinHDD
Description SystemerrororPacketdataerror
Remedy
It'sduetodatacorruptionorsoftwarebug.
1.StartinSafeModetoperformoverallformatwithSSTand
reinstallthesystem(System,Lang,RUI),andthenturnOFF
andthenONtheMainPowerSwitch.
2.Iftheabovemeasuresdonotsolvetheproblem,itcanbe
causedbyfailurewiththeHDD;therefore,replacetheHDD
andreinstallthesystem.
E602
0925
00
Title
ErrorinHDD
Description WriteAbort
Remedy
Thedocumentdata(suchasBOXontheHDD)canbe
damaged.
1.EntertheapplicableCHK-TYPE=3inthepartitionto
performHDD-CHECK(duration:severalminutestoseveral
dozensofminutes),andthenturnOFFandthenONthe
power.
2.Iftheabovemeasuresdonotsolvetheproblem,enterthe
applicableCHK-TYPE=3inthepartitiontoexecuteHDD-
CLEAR,andthenturnOFFandthenONtheMainPower
Switch.
(UseSSTtoperformreformat/reinstallationinthecaseof
thefollowing:BOOTDEV,BOOTDEV2andAPL_SEND)
3.Iftherestillremainstheproblem,itcanbecausedby
failurewiththeHDD;therefore,replacetheHDDand
reinstallthesystem.
E602
1000
00
Title
ErrorinHDD
Description FailureincontactwithHDDorvxWorkssystemerror
Remedy
1.Checkthecableandpowerconnector.
2.Iftheabovemeasuresdonotsolvetheproblem,startin
SafeModetoperformoverallformatusingSSTandreinstall
thesystem(System,Lang,RUI),andthenturnOFFand
thenONtheMainPowerSwitch.
3.Iftherestillremainstheproblem,itcanbecausedby
failurewiththeHDD;therefore,replacetheHDDand
reinstallthesystem.
7-44
Description
7-44

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents