Ofstac-K; Ofstacm2; Ofstacy2; Ofstacc2 - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

COPIER>ADJUST>HV-PRI

OFSTAC-K

AdjofBkclrchargeACcurrent:1/1SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforBk.
Asthevalueisincrementedby1,thecurrentvalueisincreased
by20uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Ifthevalueistoolarge,thelifeofthePhotosensitiveDrum
becomesshorter.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
1minute
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTAC-Y,OFSTAC-M,
OFSTAC-C
Relatedusermode
-
Supplement/memo
-

OFSTACY2

AdjofYclrchargeACcurrent:1/2SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforYat1/2speed.
Asthevalueisincrementedby1,theoffsetisincreasedby50
uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTACM2,OFSTACC2,
OFSTACK2
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>ADJUST>HV-PRI

OFSTACM2

AdjofMclrchargeACcurrent:1/2SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforMat1/2speed.
Asthevalueisincrementedby1,theoffsetisincreasedby50
uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTACY2,OFSTACC2,
OFSTACK2
Relatedusermode
-
Supplement/memo
-

OFSTACC2

AdjofCclrchargeACcurrent:1/2SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforCat1/2speed.
Asthevalueisincrementedby1,theoffsetisincreasedby50
uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
Usecase
Attheoccurrenceofanimagedensityfailure
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTACY2,OFSTACM2,
OFSTACK2
Relatedusermode
-
Supplement/memo
-
8-202
8-202