PART-CHK
COPIER>FUNCTION>PART-CHK

CL

Specification of operation Clutch
Lv.1
Details
Tospecifytheclutchtooperate.
Usecase
WhenreplacingtheClutch/checkingtheoperation
Adj/set/operatemethod
Enterthevalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
1to5
1:Multi-purposePickupClutch(CL1)
2:TonerSupplyClutch(Y)(CL2)
3:TonerSupplyClutch(M)(CL3)
4:TonerSupplyClutch(C)(CL4)
5:TonerSupplyClutch(Bk)(CL5)
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>PART-CHK>CL-ON
Relatedusermode
-
Supplement/memo
-

CL-ON

OperationcheckofClutch
Lv.1
Details
To start operation of the clutch specified with CL.
Duringoperation,ON/OFFisrepeatedwithanintervalof3
seconds.
Usecase
WhenreplacingtheClutch/checkingtheoperation
Adj/set/operatemethod
1)DrivetheITBandDrum(COPIER>FUNCTION>MISC-P>
MAIN-DRV).
2)Selecttheitem,andthenpressOKkey.
3)CheckthegearoftheTransferCleaningAssembly.
Caution
-
Display/adj/setrange
During operation: ACTIVE, When operation finished normally:
OK!
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
Approx.1minute
Relatedservicemode
COPIER>FUNCTION>MISC-P>MAIN-DRV
COPIER>FUNCTION>PART-CHK>CL
Relatedusermode
-
Supplement/memo
RemovetheInnerCoversothattheClutchcanbechecked
visually.
8

8

COPIER>FUNCTION>PART-CHK
FAN
Specification of operation Fan
Lv.1
Details
TospecifytheFantooperate.
Usecase
WhenreplacingtheFan/checkingtheoperation
Adj/set/operatemethod
Enterthevalue,andthenpressOKkey.
Caution
-
Display/adj/setrange
1to10
1:FixingHeatExhaustFan1(FM1)
2:FixingHeatExhaustFan2(FM2)
3:Notused
4:ProcessCartridgeFan(Rear)(FM4)
5:FixingCoolingFan(Front)(FM5)
6:FixingCoolingFan(Rear)(FM6)
7:DeliveryFan1(FM7)
8:SecondaryTransferExhaustFan(FM8)
9:DeliveryFan2(FM9)
10:ProcessCartridgeFan(Front)(FM10)
Unit
-
Appropriatetargetvalue
-
Defaultvalue
1
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>PART-CHK>FAN-ON
Relatedusermode
-
Supplement/memo
-
FAN-ON
OperationcheckofFan
Lv.1
Details
To start operation check of the Fan specified by FAN.
Usecase
WhenreplacingtheFan/checkingtheoperation
Adj/set/operatemethod
Selecttheitem,andthenpressOKkey.
Caution
-
Display/adj/setrange
During operation: ACTIVE, When operation finished normally:
OK!
Unit
-
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
1minute
Relatedservicemode
COPIER>FUNCTION>PART-CHK>FAN
Relatedusermode
-
Supplement/memo
-
8-247
8-247

Hide quick links: