Img-Fix Table; Delv-Fan; Fx-S-Tmp; Tmp-Tbl2 - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

IMG-FIX
COPIER>OPTION>IMG-FIX

DELV-FAN

ON/OFFofcondensationpreventionmode
Lv.2
Details
TosetON/OFFofcondensationcontrolmode.
When"1:ON"isset,internalandexternaltemperaturesare
compared,andifneeded,turnONtheProcessCartridgeFan
(Front)(FM10).
Usecase
Whencondensationoccurs
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:OFF,1:ON
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo

FX-S-TMP

SettingofITOPcontroltemp:plainppr
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforplainpaper(64
to81g/m2)in1/1speed.
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeonplainpaper
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-10degC,-1:-5degC,0:0degC,1:5degC,2:10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8

8

COPIER>OPTION>IMG-FIX
DRM-RTIM
Setexeintervaldrumlineprevsequence
Lv.2
Details
TosetthetimeintervaltorotatethePhotosensitiveDrumat
standbyorsleepmode.
Whenadeviceisleftforalongperiodoftime,adrumpitchline
occurs.Topreventthis,rotatethePhotosensitiveDrumatthe
specified interval for 300 msec only.
Asthevalueisincrementedby1,theintervalisextendedby5
minutes.
Ifusersdonotcareaboutthedrumpitchlineortheywantto
reducetherotationinterval,increasethevalue.
Usecase
Extendtheintervalfortheuserswhodonotcareaboutthedrum
pitchlineafterthemachineisleftorwhowanttoreducethe
numberofstart-up.
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to12
0:Notexecuted
Unit
5minutes
Appropriatetargetvalue
Defaultvalue
3
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo

TMP-TBL2

Setting of fixing control temp: heavy 1
Lv.1
Details
To set the offset of fixing control temperature for heavy paper 1
(106to163g/m2).
Asthevalueisincreasedby1,thecontroltemperatureis
increasedby5degC.
Increase the value when the fixing failure occurs.
Decrease the value when the fixing offset occurs.
Usecase
When the offset or fixing failure occurs on heavy paper 1
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-10degC,-1:-10degC,0:0degC,1:+5degC,2:+10deg
C
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo