COPIER>OPTION>FNC-SW
ARCDT-SW
ON/OFFofARCDATcontrol
Lv.1
Details
TosetON/OFFofARCDATcontrol.
When "1: OFF" is set, the result of ARCDAT control is not reflected
toLUT.
Whenthehuevariationoccursinthecaseoffailurevalue
displayedinCOPIER>DISPLAY>HT-C,turnOFFtheARCDAT
controlonceandcheckthehue.
Ifhuevariationisalleviated,analyzethecauseofARCDATcontrol
error(developer,PatchSensor,etc.).
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Makesuretoset"0:ON"againwhenARCDATcontrolrecovers.
Display/adj/setrange
0to1
0:ON,1:OFF
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
COPIER>DISPLAY>HT-C
Relatedusermode
Supplement/memo
SJOB-CL
Setofscanjobcancelingbylogout
Lv.1
Details
Tosetwhethertocancelthescanjobinoperationbylogoutofthe
user.
Usecase
Uponuser'srequest
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-Thejobinscanningoperationcannotbecanceled.
-Cancelbylogoutiskeptinthelog.
Display/adj/setrange
0to1
0:Disabled,1:Enabled
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
Scanjob:Ajobafterthescanningoperationiscompleted.
8
8
COPIER>OPTION>FNC-SW
PT-W-SET
Settonerbandwidthatinirotn:transp
Lv.2
Details
TosetthetonerbandwidththatiscreatedontheITBattheinitial
rotationwhenfeedingthetransparency.
Asthevalueisincrementedby1,thetonerbandwidthis
increasedby10mm.
Whenthevalueisincreased,imagefailureduetoTransfer
CleaningBladeboundisreducedwhenfeedingthetransparency.
Usecase
WhenimagefailureduetoTransferCleaningBladeboundoccurs
ontransparency
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to10
Unit
10mm
Appropriatetargetvalue
Defaultvalue
5
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
DELV-FN2
ON/OFFofDeliveryFan
Lv.2
Details
TosetON/OFFoftheDeliveryFan2(FM9)ata1-sidedjob.
Usecase
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
0to1
0:OFF,1:ON
Unit
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8-276