Ecode Detail
Location
Item
Code
E56F
0001
05
Title
EntranceRollerRelease/StopperHPMotorfailstomove
fromHP
Description At initial rotation, when the Motor rotates for specified period
oftimeandcannotmovefromHP,itisdetectedasanerror
if the same symptom occurs again after the first retry.
Remedy
1.CheckiftheMotor(M6)Connectorisphysicallyremoved.
2.CheckiftheMotorfailureoccurs.
3.CheckiftheEntranceRollerRelease/StopperHPSensor
(S5)Connectorisphysicallyremoved.
4.CheckiftheEntranceRollerRelease/StopperHPSensor
(S5)failureoccurs.
E56F
0002
05
Title
EntranceRollerRelease/StopperHPMotorfailstoreturnto
HP
Description At initial rotation, when the Motor rotates for specified period
oftimeandcannotreturntoHP,itisdetectedasanerrorif
the same symptom occurs again after the first retry.
Remedy
1.CheckiftheMotor(M6)Connectorisphysicallyremoved.
2.CheckiftheMotorfailureoccurs.
3.CheckiftheEntranceRollerRelease/StopperHPSensor
(S5)Connectorisphysicallyremoved.
4.CheckiftheEntranceRollerRelease/StopperHPSensor
(S5)failureoccurs.
E571
0001
05
Title
GripperOpen/CloseMotorfailstomovefromHP
Description At initial rotation, when the Motor rotates for specified period
oftimeandcannotmovefromHP,itisdetectedasanerror
if the same symptom occurs again after the first retry.
Remedy
1.CheckiftheMotor(M7)Connectorisphysicallyremoved.
2.CheckiftheMotorfailureoccurs.
3.CheckiftheGripperArmHPSensor(S13)Connectoris
physicallyremoved.
4.CheckiftheGripperUnitHPSensor(S7)failureoccurs.
E571
0002
05
Title
GripperOpen/CloseMotorfailstoreturntoHP
Description At initial rotation, when the Motor rotates for specified period
oftimeandcannotreturntoHP,itisdetectedasanerrorif
the same symptom occurs again after the first retry.
Remedy
1.CheckiftheMotor(M7)Connectorisphysicallyremoved.
2.CheckiftheMotorfailureoccurs.
3.CheckiftheGripperArmHPSensor(S13)Connectoris
physicallyremoved.
4.CheckiftheGripperUnitHPSensor(S7)failureoccurs.
7
Description
7
Ecode Detail
Location
Item
Code
E575
0001
05
Title
GripperUnitMoveMotorfailstomovefromHP
Description At initial rotation, when the Motor rotates for specified period
oftimeandcannotmovefromHP,itisdetectedasanerror
if the same symptom occurs again after the first retry.
Remedy
1.CheckiftheMotor(M2)Connectorisphysicallyremoved.
2.CheckiftheMotorfailureoccurs.
3.CheckiftheGripperUnitHPSensor(S7)Connectoris
physicallyremoved.
4.CheckiftheGripperUnitHPSensor(S7)failureoccurs.
E575
0002
05
Title
GripperUnitMoveMotorfailstoreturntoHP
Description At initial rotation, when the Motor rotates for specified period
oftimeandcannotreturntoHP,itisdetectedasanerrorif
the same symptom occurs again after the first retry.
Remedy
1.CheckiftheMotor(M2)Connectorisphysicallyremoved.
2.CheckiftheMotorfailureoccurs.
3.CheckiftheGripperUnitHPSensor(S7)Connectoris
physicallyremoved.
4.CheckiftheGripperUnitHPSensor(S7)failureoccurs.
E584
8001
05
Title
Shutterhomepositionerror
Description 1.Theshutterhomepositionsensor(PI113)isfaulty.
2. The wiring between the finisher controller PCB and stack
ejection motor, and between the finisher controller PCB and
shutterclutchisfaulty.
3.Theshuttermechanismisfaulty.
4.Thestackejectionmotor(M102),shutterclutch(CL101),
angstackejectionlowerrollerclutch(CL102)isfaulty.
5. The finisher controller PCB is faulty.
Remedy
Thestaplerdoesnotleavetheshutterhomepositionwhen
thestackejectionmotorhasbeendrivenfor30seconds.
E584
0002
05
Title
Shutterhomepositionerror
Description 1.Theshutterhomepositionsensor(PI113)isfaulty.
2. The wiring between the finisher controller PCB and stack
ejection motor, and between the finisher controller PCB and
shutterclutchisfaulty.
3.Theshuttermechanismisfaulty.
4.Thestackejectionmotor(M102),shutterclutch(CL101),
angstackejectionlowerrollerclutch(CL102)isfaulty.
5. The finisher controller PCB is faulty.
Remedy
Thestaplerdoesnotreturntotheshutterhomeposition
whenthestackejectionmotorhasbeendrivenfor3
seconds.
7-23
Description
7-23