COPIER>ADJUST>HV-TR

2TR-P1

SectrnsATVCtgtcrrnt:lowhmdycrd1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stsideof
postcard/envelopeatsecondarytransferATVCcontrol(inlow
humidity).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

2TR-P2

SectrnsATVCtgtcrrnt:lowhmdycrd2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
postcard/envelopeatsecondarytransferATVCcontrol(inlow
humidity).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>ADJUST>HV-TR

2TR-H1

SectrnsATVCtgtcrrnt:lowhmdyhvy1st
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe1stside
ofheavypaperatsecondarytransferATVCcontrol(inlow
humidity).
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

2TR-H2

SectrnsATVCtgtcrrnt:lowhmdyhvy2nd
Lv.1
Details
Toadjusttheoffsetvalueoftargetcurrentforthe2ndsideof
heavypaperatsecondarytransferATVCcontrol(inlowhumidity)
Usecase
Whenadjustingthesecondarytransferbiasaccordingtothe
conditions
Adj/set/operatemethod
Enterthesettingvalue(switchnegative/positiveby-/+key)and
pressOKkey.
Caution
-
Display/adj/setrange
-128to127
Unit
0.2uA
Appropriatetargetvalue
-20to20
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-