COPIER>FUNCTION>INSTALL
INISET-Y
ExeofYDevAss'yinitialinstallmode
Lv.1
Details
Toautomaticallyexecuteoperationnecessaryforinitial
installationoftheYDevelopingAssembly.
1.IdlerotationoftheDevelopingAssembly
2.InitializationoftheTonerDensitySensor
3.SecondarytransferATVCcontrol
4.Patchlightintensitycorrection
5.Backgroundcorrection
6.Dischargecurrentcontrol
7.PrimarytransferATVCcontrol
8.InitializationofthePatchSensor
9.Autoregistration
10. D-maxcontrol
11. D-halfcontrol
12. ARCDAT-Lite(createsthetarget)
13. CleaningoftheSecondaryTransferOuterRoller(twice)
14. CounterresetoftheDevelopingAssembly
Usecase
WhenreplacingtheYDevelopingAssembly
Adj/set/operatemethod
Selecttheitem,andthenpressOKkey.
•
Caution
WheninstallingthemachineorreplacingtheDeveloping
Assemblyofothercolor,donotusethisitem..
•
Executethisitemaftersetting"AINR-OFF"to"1:ON".
Display/adj/setrange
Duringoperation:xxxsecond(remainingtime),Atnormal
termination:OK,Atabnormaltermination:NG
Unit
-
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
155seconds
Relatedservicemode
COPIER>FUNCTION>INSTALL>INISET-M,INISET-C,
INISET-K,INISET-4,AINR-OFF
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>FUNCTION>INSTALL
INISET-M
ExeofMDevAss'yinitialinstallmode
Lv.1
Details
Toautomaticallyexecuteoperationnecessaryforinitial
installationoftheMDevelopingAssembly.
1.IdlerotationoftheDevelopingAssembly
2.InitializationoftheTonerDensitySensor
3.SecondarytransferATVCcontrol
4.Patchlightintensitycorrection
5.Backgroundcorrection
6.Dischargecurrentcontrol
7.PrimarytransferATVCcontrol
8.InitializationofthePatchSensor
9.Autoregistration
10. D-maxcontrol
11. D-halfcontrol
12. ARCDAT-Lite(createsthetarget)
13. CleaningoftheSecondaryTransferOuterRoller(twice)
14. CounterresetoftheDevelopingAssembly
Usecase
WhenreplacingtheMDevelopingAssembly
Adj/set/operatemethod
Selecttheitem,andthenpressOKkey.
•
Caution
WheninstallingthemachineorreplacingtheDeveloping
Assemblyofothercolor,donotusethisitem..
•
Executethisitemaftersetting"AINR-OFF"to"1:ON".
Display/adj/setrange
Duringoperation:xxxsecond(remainingtime),Atnormal
termination:OK,Atabnormaltermination:NG
Unit
-
Appropriatetargetvalue
-
Defaultvalue
-
Requiredtime
155seconds
Relatedservicemode
COPIER>FUNCTION>INSTALL>INISET-Y,INISET-C,
INISET-K,INISET-4,AINR-OFF
Relatedusermode
-
Supplement/memo
-
8-234
8-234