Tgt-C-M3; Tgt-C-C3; Sum-A-Y2; Sum-A-M2 - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

COPIER>DISPLAY>HT-C

TGT-C-M3

ARCDATscrnCM-colortargetVL(1/3SPD)
Lv.2
Details
TodisplaytheM-patchtargetvalueofscreenCinARCDAT
controlat1/3speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

TGT-C-C3

ARCDATscrnCC-colortargetVL(1/3SPD)
Lv.2
Details
TodisplaytheC-patchtargetvalueofscreenCinARCDAT
controlat1/3speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
TGT-C-K3
ARCDATscrnCBk-clrtargetVL(1/3SPD)
Lv.2
Details
TodisplaytheBk-patchtargetvalueofscreenCinARCDAT
controlat1/3speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>DISPLAY>HT-C

SUM-A-Y2

ARCDATscrnAY-clrctrldiffer(1/2SPD)
Lv.2
Details
TodisplayY-patchcontroldifferenceofscreenAinARCDAT
controlat1/2speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resetthe
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

SUM-A-M2

ARCDATscrnAM-clrctrldiffer(1/2SPD)
Lv.2
Details
TodisplayM-patchcontroldifferenceofscreenAinARCDAT
controlat1/2speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resetthe
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-111
8-111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents