COPIER>DISPLAY>HT-C
TGT-C-M3
ARCDATscrnCM-colortargetVL(1/3SPD)
Lv.2
Details
TodisplaytheM-patchtargetvalueofscreenCinARCDAT
controlat1/3speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
TGT-C-C3
ARCDATscrnCC-colortargetVL(1/3SPD)
Lv.2
Details
TodisplaytheC-patchtargetvalueofscreenCinARCDAT
controlat1/3speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
TGT-C-K3
ARCDATscrnCBk-clrtargetVL(1/3SPD)
Lv.2
Details
TodisplaytheBk-patchtargetvalueofscreenCinARCDAT
controlat1/3speed.
Usecase
WhencheckingARCDATcontroloperation
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
0to1023
Unit
-
Appropriatetargetvalue
0to700
Defaultvalue
-
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>DISPLAY>HT-C
SUM-A-Y2
ARCDATscrnAY-clrctrldiffer(1/2SPD)
Lv.2
Details
TodisplayY-patchcontroldifferenceofscreenAinARCDAT
controlat1/2speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resetthe
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
SUM-A-M2
ARCDATscrnAM-clrctrldiffer(1/2SPD)
Lv.2
Details
TodisplayM-patchcontroldifferenceofscreenAinARCDAT
controlat1/2speed.
Whenhuevariationoccursandthevalueshownisnotinthe
tolerablerange,executeautogradationadjustment(resetthe
targetvalue).CheckthePatchSensororreplacethedeveloper
ifnotcorrected.
Usecase
Whenhuevariationoccurs
Adj/set/operatemethod
-
Caution
Takenecessaryactioninaccordancewiththeinstructionsfrom
theQualitySupportDivision.
Display/adj/setrange
-1023to1023
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-111
8-111