COPIER>ADJUST>ADJ-XY
STRD-POS
AdjreadpstninDADFmode:frontside
Lv.1
Details
ToadjustthereadingpositionatDADFreading(frontside).
WhenreplacingtheReaderControllerPCB/clearingRAMdata,
enterthevalueofservicelabel.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
1to200
Unit
0.1mm
Appropriatetargetvalue
-
Defaultvalue
110
Requiredtime
-
Relatedservicemode
COPIER>FUNCTION>INSTALL>STRD-POS
Relatedusermode
-
Supplement/memo
-
ADJ-X-MG
Adjimgratioinbookmod:vertscan[frt]
Lv.1
Details
To make a fine adjustment of image magnification in vertical
scanningdirectionatcopyboardreading.
WhenreplacingtheReaderControllerPCB/clearingRAMdata,
enterthevalueofservicelabel.
As the value is incremented by 1, the image magnification
changesby0.01%.
+:Enlarge
-:Reduce
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
-50to50
Unit
0.01%
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>ADJUST>ADJ-XY
ADJY-DF2
AdjimgpstninDADFmod:horizscan[bck]
Lv.1
Details
Toadjusttheimagepositionofbacksideinhorizontalscanning
directionatsimultaneousduplexreading.
WhenreplacingtheReaderControllerPCB/clearingRAMdata,
enterthevalueofservicelabel.
Asthevalueisincrementedby1,theimagepositionmovesto
therearsideby0.1mm.
Usecase
WhenreplacingtheReaderControllerPCB/clearingRAMdata
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Afterthesettingvalueischanged,writethechangedvalueinthe
servicelabel.
Display/adj/setrange
56to220
Unit
0.1mm
Appropriatetargetvalue
-
Defaultvalue
120
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-