Fxs-Tmp2 - Fxs-Tmp5 - Canon imageRUNNER ADVANCE C5045 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5045 Series:
Table of Contents

Advertisement

COPIER>OPTION>IMG-FIX
FXS-TMP2
SettingofITOPcontroltemp:heavy1
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforheavypaper
1(106to163g/m2).
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeonheavypaper1
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-15degC,-1:-7degC,0:0degC,1:+5degC,2:+10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
FXS-TMP3
SettingofITOPcontroltemp:heavy2
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforheavypaper2
(164to209g/m2).
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeonheavypaper2
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-15degC,-1:-7degC,0:0degC,1:+5degC,2:+10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8

8

COPIER>OPTION>IMG-FIX
FXS-TMP4
SettingofITOPcontroltemp:heavy3
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforheavypaper3
(210to256g/m2).
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeonheavypaper3
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-15degC,-1:-7degC,0:0degC,1:+5degC,2:+10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
FXS-TMP5
SettingofITOPcontroltemp:thinppr
Lv.1
Details
TosettheoffsetofITOPcontroltemperatureforthinpaper.
Asthevalueisincrementedby1,thecontroltemperatureis
increasedby5degC.
Usecase
Whenunevenglossoccursintheareathatis94mmfromthe
leadingedgeonthinpaper
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
Display/adj/setrange
-2to2
-2:-15degC,-1:-7degC,0:0degC,1:+5degC,2:+10degC
Unit
5degC
Appropriatetargetvalue
Defaultvalue
0
Requiredtime
Relatedservicemode
Relatedusermode
Supplement/memo
8-321