CNCT-RLZ

Settingofconnectionserializefunction
Lv.2
Details
Connectionserializeisafunctiontoassurejobgroupingfunction
ofimageWAREOutputManagerSelectEditionV1.0.
Thesettingtoenablethismodecanavoidjobrearrangement
becausethemachinedoesnotreceivejobdatafromother
connectionuntilitcompletesjobdatareceptionfromthecurrent
connection.
Usecase
Uponuser'srequest
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to1
0:OFF,1:ON
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
Connection:Connectiontobeestablishedthroughnetwork
betweenmultiplehosts(PC,etc).
Jobgroupingfunction:AfunctionofimageWAREOutput
ManagerSelectEditionV1.0topreventjobinterruptionfrom
otherPCbygroupjob(sendingmultiplejobsin1sessionatjob
transmission).

COUNTER7

Settingofsoftwarecounter7
Lv.1
Details
Tosetcountertypeforsoftwarecounter7ontheCounterCheck
screen.
Usecase
Uponuser'srequest
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to999
0:Notregistered
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8

8

COPIER>OPTION>USER

COUNTER8

Settingofsoftwarecounter8
Lv.1
Details
Tosetcountertypeforsoftwarecounter8ontheCounterCheck
screen.
Usecase
Uponuser'srequest
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to999
0:Notregistered
Unit
-
Appropriatetargetvalue
-
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-

2C-CT-SW

Setofcolorcounterat2-colormode
Lv.2
Details
Tosetwhethertousethemonocolorcounterorfullcolorcounter
forcount-upin2-colormode.
Usecase
-
Adj/set/operatemethod
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to1
0:Monocolorcounter,1:Fullcolorcounter
Unit
-
Appropriatetargetvalue
-
Defaultvalue
1
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-