COPIER>OPTION>ACC
OUT-TRAY
SetofThirdDeliveryTrayinstallation
Lv.1
Details
TosetwhethertheThirdDeliveryTrayisinstalled.
WhentheThirdDeliveryTrayisinstalled,set"1".
Usecase
WheninstallingtheThirdDeliveryTray
Adj/set/operate
1)Enterthesettingvalue,andthenpressOKkey.
method
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to1
0:Notinstalled,1:Installed
Unit
-
Appropriatetarget
-
value
Defaultvalue
0
Requiredtime
-
Relatedservicemode -
Relatedusermode
-
Supplement/memo
-
CC-SPSW
SupportsettingofcontrolcardI/F
Lv.2
Details
Tosetsupportlevelforcontrolcard(CCIV/CCV)interface.
Tokeepprocessingperformanceofprinterengine,select"1:Priority
onspeed".
Tocorrectlystoptheoutputbytheupperlimitnumberofsheets,
select"2:Priorityonupperlimitnumberofsheets".
Usecase
Uponuser'srequest(whenconnectingtotheexternalcounter
managementsystemusingthecontrolcardinterface)
Adj/set/operate
1)Enterthesettingvalue,andthenpressOKkey.
method
2)TurnOFF/ONthemainpowerswitch.
Caution
Withpriorityonspeed,outputcannotbecorrectlystoppedbythe
upperlimitnumberofsheets.
Withpriorityontheupperlimitnumberofsheets,processing
performanceoftheprinterengineisdecreaseddependingonpickup
location.
Display/adj/setrange
0to2
0:Nosupport,1:Priorityonspeed,2:Priorityonupperlimitnumber
ofsheets
Unit
-
Appropriatetarget
-
value
Defaultvalue
0
Requiredtime
-
Relatedservicemode -
Relatedusermode
-
Supplement/memo
-
8
8
COPIER>OPTION>ACC
USB-MSK
LimitforUSBhostusingcannel
Lv.1
Details
TosetthechannelthatcannotusetheUSBhost.
Usecase
-
Adj/set/operate
0to2
method
0:Notlimited,1:CH1,2:Notused
Caution
-
Display/adj/setrange
1)Enterthesettingvalue,andthenpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Unit
-
Appropriatetarget
-
value
Defaultvalue
0
Requiredtime
-
Relatedservicemode -
Relatedusermode
-
Supplement/memo
-
UNIT-PRC
SettingofCoinManagercurrencyunit
Lv.2
Details
TosetcurrencyunittobehandledwithCoinManager
Usecase
AtinstallationofCoinManager
Adj/set/operate
1)Enterthesettingvalue,andthenpressOKkey.
method
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
0to6
0:Japaneseyen,1:Euro,2:Pound,3:SwissFranc.4:Dollar,5:No
currencyunit(nofractionalunit),6:Nocurrencyunit(withfractional
unit)
Unit
-
Appropriatetarget
-
value
Defaultvalue
0
Requiredtime
-
Relatedservicemode -
Relatedusermode
-
Supplement/memo
-
8-362
8-362