Cut a small section of the 2.5" hose (about 4") and fasten one end to the supplied hose adapter.
Install the other end to the top plenum on the back of the Evaporator unit (use a zip tie to hold each end in
place) and route the hose to the bottom of the driver side inner footbox wall. Note the general location of
the hose so you can locate the opening for the duct.
Using the supplied duct as a template you will need to trim an opening in the footbox inner wall
aluminum.
Slide the hose over the duct and rivet the duct to the aluminum panel.
Repeat for the passenger side.