Vocal Messages; Installer Access; Daylight Savings; Entry/Exit Trouble - Electronics Line CommPact Installation Manual

Hide thumbs Also See for CommPact:
Table of Contents

Advertisement

Hata! Burada görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın. Hata! Burada
görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın.
Time counter is reset each time the system is disarmed.
9.10.

Vocal Messages

The Vocal Messages option allows you to enable/disable vocal annunciation of system status. When 
this  feature  is  enabled,  the  system  plays  a  short  message  to  announce  events  such  as  arming  and 
disarming. 
To program the Vocal Messages option: 
1.
From the Programming menu, select System Options, Vocal Message [9411]. 
2.
Select Enabled or Disabled. 
The availability of the Vocal Message annunciation feature is hardware dependent. 
9.11.

Installer Access

The Installer Access option determines if the Installer code can access the system at all times or only 
after  the  Master  code  provides  authorization with the  Enable  Programming  command – see p 32, 
4.7.12 Enable Programming. 
To program the Installer Access option: 
1.
From the Programming menu, select System Options, Instal. Access [9412]. 
2.
Select Always or User Initiated. 
9.12.

Daylight Savings

Using the Daylight Savings option, the system is able to automatically adjust its clock twice a year 
according to the national adjustment to Daylight Saving Time. 
Two options are available: 
Europe – the clock is adjusted forward 1hr on the last Sunday in March at 1am, the 
clock is adjusted back 1hr on the last Sunday in October at 1am. 
USA– the clock is adjusted forward 1hr on the second Sunday in March at 2am, the 
clock is adjusted back 1hr on the first Sunday of November at 2am. 
To program the Daylight Savings option: 
1.
From the Programming menu, select System Options, Daylight Savings [9413]. 
2.
Select Europe, USA or Disabled. 
9.13.

Entry/Exit Trouble

If  this  function  is  enabled,  the  system  canʹt  be  armed  when  the  Exit  Delay  expires,  if  one of the 
following conditions is present: 
An entry/exit zone is open; 
Tamper Alarm from a zone during exit (if not restored before the exit delay expires); 
Zone Active when Exit Delay expires. 
The event is then sent to the central station account. 
To program the Entry/exit Trouble option: 
1.
From the Programming menu, select System Options, Entry Exit TR [9415]. 
2.
Select Enabled or Disabled. 
CommPact Installation Manual
 