Hata! Burada görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın. Hata! Burada
görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın.
Time counter is reset each time the system is disarmed.
9.10.
Vocal Messages
The Vocal Messages option allows you to enable/disable vocal annunciation of system status. When
this feature is enabled, the system plays a short message to announce events such as arming and
disarming.
To program the Vocal Messages option:
1.
From the Programming menu, select System Options, Vocal Message [9411].
2.
Select Enabled or Disabled.
The availability of the Vocal Message annunciation feature is hardware dependent.
9.11.
Installer Access
The Installer Access option determines if the Installer code can access the system at all times or only
after the Master code provides authorization with the Enable Programming command – see p 32,
4.7.12 Enable Programming.
To program the Installer Access option:
1.
From the Programming menu, select System Options, Instal. Access [9412].
2.
Select Always or User Initiated.
9.12.
Daylight Savings
Using the Daylight Savings option, the system is able to automatically adjust its clock twice a year
according to the national adjustment to Daylight Saving Time.
Two options are available:
Europe – the clock is adjusted forward 1hr on the last Sunday in March at 1am, the
clock is adjusted back 1hr on the last Sunday in October at 1am.
USA– the clock is adjusted forward 1hr on the second Sunday in March at 2am, the
clock is adjusted back 1hr on the first Sunday of November at 2am.
To program the Daylight Savings option:
1.
From the Programming menu, select System Options, Daylight Savings [9413].
2.
Select Europe, USA or Disabled.
9.13.
Entry/Exit Trouble
If this function is enabled, the system canʹt be armed when the Exit Delay expires, if one of the
following conditions is present:
An entry/exit zone is open;
Tamper Alarm from a zone during exit (if not restored before the exit delay expires);
Zone Active when Exit Delay expires.
The event is then sent to the central station account.
To program the Entry/exit Trouble option:
1.
From the Programming menu, select System Options, Entry Exit TR [9415].
2.
Select Enabled or Disabled.
CommPact Installation Manual