4.2.

Cancel Report

This feature allows the user to cancel false alarms. Cancel Report behavior depends on time when it 
is performed. If the user selects Cancel Report: 
...before the alarm/restore message is sent, all the pending alarm or restore messages 
in the queue are aborted and marked ʺCancelledʺ in the event log. 
...within 5 minutes since an alarm, a Cancel Report event and the user number are 
sent to the Central Station; 
...at the moment when the event is being reported (communication in progress), the 
event reporting is not cancelled; 
Non‐alarm events (system trouble, arm/disarm etc.) are not aborted by Cancel Report. 
To activate cancel report: 
From the main menu, select Cancel Report. [1]. 
4.3.

Zone Bypassing/Unbypassing

When  a  detector  is  bypassed,  it  is  ignored  by  the  system  and  does  not  generate  an  alarm  when 
triggered. 
To bypass or unbypass a detector: 
1.
From the Bypass Zones menu, select Bypass/Unbyp. [21]. 
2.
Using the arrow keys, scroll to the detector you want to bypass or unbypass. 
3.
Press ʹ√ʹ to change the bypass status. 
4.
Press 'Χ'; Save Changes? is displayed. 
5.
Press ʹ√ʹ to confirm the changed bypass status. 
To unbypass all detectors: 
1.
From the Bypass Zones menu, select Unbypass All [22]. 
2.
Press ʹ√ʹ; all detectors are unbypassed. 
All bypassed zones are automatically unbypassed when the system is disarmed.  
A Fire zone cannot be bypassed.
4.4.

User Codes

The Control System supports up to 32 individual user codes. Each of these codes is four digits long. 
Most system operations require you to enter a valid user code. The ability to perform an operation 
is  defined  by  your  user  code's  authorization  level.  These  authorization  levels  are  pre‐defined  for 
each code as explained below. 
Codes 1‐29 can be edited only by the Master code.  
The Installer code and the Central Station TWA Code can be edited only by the installer.