9.4.
AC Loss Delay
The AC Loss Delay is the amount of time that has to elapse before an AC Loss report is sent to the
central station. If AC power is restored before the event message is sent, the event message is
canceled and will not be sent. You can program an AC Loss Delay to be between 1 and 255 minutes
after the system first senses the AC loss condition. Alternatively you can program a random AC
Loss Delay.
The AC Restore message is also sent using the same method described above. AC Restore is
reported only if the AC Loss report was sent.
To program the AC Loss Delay:
1.
From the Programming menu, select System Options, AC Loss Delay [9404].
2.
Enter a delay time (001‐255 minutes) or enter 000 if you require the system to choose a
random AC Loss Delay, and then press ʹ√ʹ.
9.4.1.
Random AC Loss Delay
In the event of AC loss, an event message is sent to the central station between 15 and 30 minutes
after the AC loss condition is sensed. The system chooses this delay at random in order to prevent
the central station being inundated by simultaneous AC Loss reports in the event of a regional
power cut.
9.5.
Display Options
The following options relate to the information the system displays on the front panel keypad.
9.5.1.
Arm Status Display
The Arm Status Display includes the current arm status and any trouble conditions that may exist
within the system. You can program the system to display this information at all times, only for two
minutes, or only for 30 seconds after arming or disarming the system.
To program the Arm Status Display options:
1.
From the Programming menu, select System Options, Display, and Arm Status [94051].
2.
Select Display Always, Display 2 Min, or Display 30 sec.
9.5.2.
Banner
The Banner is the 16‐character text that you can program to appear on the top row of the LCD display.
This text replaces the arm status if it is programmed to display for two minutes or 30 seconds only –
see p.55, 9.5.1 Arm Status Display.
To edit the Banner text:
1.
From the Programming menu, select System Options, Display, and Banner [94052].
2.
Edit the Banner text using the alphanumeric keypad, then press ʹ√ʹ.
The system never displays the Banner text if the Arm Status Display option is
programmed as Always.