AC Loss Delay

The AC Loss Delay is the amount of time that has to elapse before an AC Loss report is sent to the 
central  station.  If  AC  power  is  restored  before  the  event  message  is  sent,  the  event  message  is 
canceled and will not be sent. You can program an AC Loss Delay to be between 1 and 255 minutes 
after  the  system  first  senses  the  AC  loss  condition.  Alternatively  you  can  program  a  random  AC 
Loss Delay.  
The  AC  Restore  message  is  also  sent  using  the  same  method  described  above.  AC  Restore  is 
reported only if the AC Loss report was sent. 
To program the AC Loss Delay: 
1.
From the Programming menu, select System Options, AC Loss Delay [9404]. 
2.
Enter a delay time (001‐255 minutes) or enter 000 if you require the system to choose a 
random AC Loss Delay, and then press ʹ√ʹ. 
9.4.1.
Random AC Loss Delay
In the event of AC loss, an event message is sent to the central station between 15 and 30 minutes 
after the AC loss condition is sensed. The system chooses this delay at random in order to prevent 
the  central  station  being  inundated  by  simultaneous  AC  Loss  reports  in  the  event  of  a  regional 
power cut. 
9.5.

Display Options

The following options relate to the information the system displays on the front panel keypad. 
9.5.1.
Arm Status Display
The Arm Status Display includes the current arm status and any trouble conditions that may exist 
within the system. You can program the system to display this information at all times, only for two 
minutes, or only for 30 seconds after arming or disarming the system. 
To program the Arm Status Display options: 
1.
From the Programming menu, select System Options, Display, and Arm Status [94051]. 
2.
Select Display Always, Display 2 Min, or Display 30 sec. 
9.5.2.
Banner
The Banner is the 16‐character text that you can program to appear on the top row of the LCD display. 
This text replaces the arm status if it is programmed to display for two minutes or 30 seconds only – 
see p.55, 9.5.1 Arm Status Display. 
To edit the Banner text: 
1.
From the Programming menu, select System Options, Display, and Banner [94052]. 
2.
Edit the Banner text using the alphanumeric keypad, then press ʹ√ʹ. 
The  system  never  displays  the  Banner  text  if  the  Arm  Status  Display  option  is 
programmed as Always.  