9.6.4.
PGM Cut-off
The PGM Cut‐off is the duration for which the PGM is activated. Certain Output Trigger types are 
deactivated after the PGM Cut‐off time has expired– see p. 56, Table 9‐1. For those Output Trigger 
types that are not affected by the PGM Cut‐off, there is no need to program this option. 
If, for example, Output Trigger option is set to Full Arm, and PGM Cut‐off time is 060 seconds; then 
PGM  is  activated  by  Full  Arming  and  deactivated  by  disarming  or  by  PGM  Cut‐off  Time, 
whichever comes first. If this option is set to ʺ000ʺ (Continuous activation), PGM is activated by Full 
Arming, and deactivated by disarming. 
To program the PGM Cut‐off time: 
1.
From the Programming menu, select System Options, PGM Options, and PGM Cut‐off 
[94064]. 
2.
Enter a PGM Cut‐off time (001‐255 seconds or 000 for continuous activation), then press ʹ√ʹ. 
9.7.

"No Arm" Indication

The ʺNo Armʺ indication is a feature designed to inform the central station that the system has not 
been armed for a specified period of time. 
To define the ʺNo Armʺ indication interval: 
1.
From the Programming menu, select System Options, No Arm Ind. [9408]. 
2.
Select 1 Week, 2 Weeks, 3 Weeks, 4 Weeks or Disabled. 
The  No  Arm  event  message  is  an  unclassified  event.  This  means  that  it  does  not 
belong  to  any  event  group.  If  the  No  Arm  option  is  programmed  with  any  option 
other than ʺDisabledʺ, the event message will be sent.
9.8.

Jamming Detection

The  system  is  able  to  detect  RF  Jamming  that  is  usually  caused  by  an  intruder  attempting  to 
compromise the security system. 
To program the Jamming Detection setting: 
1.
From the Programming menu, select System Options, Jamming Det. [9409]. 
2.
Select Enabled or Disabled. 
9.9.

"No Motion" Time

The No Motion feature is designed to monitor the activity of disabled or elderly people.  
If a detector defined as No Motion (see p. 35,  7.3.1 Zone Type): 
When the system is disarmed, and the detector has not been triggered within a pre‐
defined period of time (00:00 to 72:00 hours), a No Motion event message is sent to the 
central station.  
When the system is armed, this zone behaves as Normal.  
The No Motion zone must be included in this arming mode – see p. 42, 7.3.2 Arm Set. 
To program the No Motion time: 
1.
From the Programming menu, select System Options, No Motion [9410]. 
2.
Enter the No Motion time value between 00:00 and 72:00. To disable the No Motion 
feature, enter 00:00. press ʹ√ʹ. 