3.6.5.

Perimeter Arming

Perimeter  arming  is  designed  for  when  the  occupant  intends  to  remain  inside  the  premises  and 
secure the perimeter. 
To arm the system's perimeter using the front panel keypad or Wireless Keypad: 
1.
Check if the system is ready to arm.  
2.
Press the Perimeter arming key on the keypad. 
3.
If One‐Key Arming is disabled, enter your user code. 
3.6.6.
Combination Arming
The system allows you to activate a combination of two arming methods. If you Perimeter arm the 
system,  you  may  also  activate  Full  or  Part  arming.  Likewise,  you  can  Perimeter  arm  the  system 
after activating Full or Part arming. It is not important which arming mode you choose first. 
You  can  activate  the  second  arming  mode  only  during  the  exit  delay  of  the  first  arming 
mode. When the first exit delay expires, you cannot activate a second arming mode.  
For combination arming, perform the following procedure: 
1.
Check if the system is ready to arm.  
2.
Activate the first arming mode. 
3.
If One‐Key Arming is disabled, enter your user code. 
4.
While the exit delay of the first arming mode is counting down, activate the second 
arming mode. 
5.
If One‐Key Arming is disabled, enter your user code. 
It  is  not  possible  to  activate  Full  and  Part  arming  modes  simultaneously.  It  is 
necessary to disarm first when changing from one arming mode to another arming 
mode.  
The exit delays of the two arming modes are entirely independent. The moment an arming mode is 
activated,  its  exit  delay  begins  to  count  down.  The  entry  delay  depends  on  which  detector  was 
tripped first. For example, if the detector is included in Full arming, the entry delay for Full arming 
counts down – see p.42, 7.3.2 Arm Set. If the detector is included in both activated arming modes, 
the entry delay for Perimeter arming counts down. 
Disarming cancels both active arming modes.  
3.6.7.
Disarming
When  an entry/exit detector  is tripped,  the  entry  delay counts  down;  each  arming  method has its 
own entry delay.  
To disarm the system: 
Enter a valid user code, the system is disarmed. 
You can only disarm all the active arming modes. 