Entry/Exit Timers and System Tones

This chapter explains how to program the time of the Entry/Exit delays and the tones sounded by 
the  Built‐In  Siren  and  wireless  siren  during  Exit/Entry  Delays,  arming,  disarming,  and  when  a 
trouble condition is present. 
8.1.

Entry/Exit Delay

The Entry/Exit delay timers determine the amount of time the user has to arm or disarm the system 
before an alarm is activated. 
You can program separate Entry and Exit delays for each arming method. 
To program Exit delay timers: 
1.
From the Programming menu, select Entry/Exit, Exit Delays [921]. 
2.
Select the Exit delay you want to program: Full [#1], Part [#2] or Perimeter [#3] 
3.
Enter a delay time (000‐255 seconds), then press ʹ√ʹ. 
To program Entry Delay timers: 
1.
From the Programming menu, select Entry/Exit, Entry Delays [922]. 
2.
Select the Entry Delay you want to program: Full [#1], Part [#2] or Perimeter [#3] 
3.
Enter a delay time (000‐255 seconds), then press ʹ√ʹ. 
8.2.

Arm on Exit

The Arm on Exit feature cancels the unnecessary remainder of the Exit delay that continues to count 
down  after  the  user  has  vacated  the  premises.  This  feature  automatically  arms  the  system  when  an 
Entry/Exit zone is closed during the Exit delay. 
To program the Arm on Exit option: 
1.
From the Programming menu, select Entry/Exit, Arm On Exit [923]. 
2.
Select Enabled or Disabled. 
8.3.

Supplementary Entry Delay

The Supplementary Entry Delay is a pre‐alarm feature that is employed in the event that the system 
is not disarmed during the entry delay. When the entry delay expires, the Control System's Built‐In 
Siren  is  sounded  during  an  additional  entry  delay period.  At  the end  of  the supplementary  entry 
delay, the system generates a full alarm condition; the wireless siren is sounded and an alarm event 
is reported to the central station.  
To program the Supplementary Entry Delay setting: 
1.
From the Programming menu, select Entry/Exit, Supp. Ent. Delay [924]. 
2.
Select Enabled or Disabled. 
CommPact Installation Manual
49