görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın.
Code 1: Master Code
The Master code is the highest user authorization level. With the Master code, you can edit all other 
user  codes  except  the  Installer  code,  the  Guard  code  and  the  Central  Station  TWA  Code. 
Additionally,  the  Master  code  grants  access  to  the  Event  Log,  and  the  Service  menu.  The  Master 
code  is  a  ʺcontrolledʺ  code.  Arming  and  disarming  using  this  code  causes  the  Control  System  to 
notify the central station with an Arm/Disarm event message
The  default  Master  code  is  1234.  Change  this  code  immediately  after  installing 
the system! 
Codes 2-19: Controlled Codes
When  you  use  a  controlled  user  code  for  arming  and  disarming,  the  Control  System  notifies  the 
central station with an Arm/Disarm event message. 
Codes 20-25: Non-controlled Codes
Non‐controlled codes do not cause the Control System to send Arm/Disarm event messages to the 
central station. The Control System sends a Disarm message only if you use this code to disarm the 
system after an alarm occurrence. 
Codes 26-27: Limited Codes
A  Limited  code  enables  the  user  to  issue  a  code  that  is  valid  for  one  day  only.  This  code 
automatically expires 24 hours after it has been programmed. These codes are ʺcontrolledʺ in that 
their use for Arm/Disarm is notified to the central station. 
Code 28: Duress Code
The  Duress  code  is  designed  for  situations  where  the  user  is  being  forced  to  operate  the  system. 
This user code grants access to the selected operation, while sending a Duress event message to the 
central station. 
Code 29: Telecontrol Code
The Telecontrol code is designed to enable the user to perform a number of tasks via their telephone 
using DTMF commands. Using this code, the user can call their system to arm and disarm, activate 
and  deactivate  the  PGM  output,  cancel  siren  activation  or  establish  Two‐Way  Audio 
communication.   
Code 30: Central Station TWA Code
The Central Station TWA code is designed to enable the central station operator to establish Two‐
Way Audio communication with the Control System after an alarm. This code is valid for use for 
the  first  ten  minutes  after  an  alarm  has  occurred.  This  code  can  only  be  used  for  this  specific 
purpose and does not grant access to any additional system functions such as disarming. 
Code 31: Guard Code
Guard Code is an option that allows a security guard to check the premise in case of an alarm. 
 Only if arm/disarm event group is enabled inSystem Programming 
*
*
Only if arm/disarm event group is enabled during System Programming