Hata! Burada görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın. Hata! Burada
görünmesini istediğiniz metne Heading 1 uygulamak için Giriş sekmesini kullanın.
7.3.4.
Bell (Siren)
Each zone can be programmed to activate the siren when triggered or to generate a silent alarm
where only a message is sent to the central station.
To program the Bell option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone's sub‐menu, select Bell [#05]; the zone's current Bell setting is displayed.
4.
Select either Enabled or Disabled.
Fire zones always activate the siren regardless of what is programmed for this option.
If the bell is disabled for Panic zones, this also disables all forms of alarm indication
from the on‐board keypad in the event of a Panic alarm.
I f the Bell option is enabled for Environmental or Flood zones, the system sounds trouble
tones from the keypad.
7.3.5.
Chime
When Chime is enabled, triggering the zone when the system is disarmed causes the Built‐In Siren
to chime.
To program the Chime option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone's sub‐menu, select Chime [#06]; the zone's current Chime setting is
displayed.
4.
Select either Enabled or Disabled.
7.3.6.
Force Arm
Force arming enables you to arm the system when the system is not ready. For example, a door that
is protected by a magnetic contact is open. You may arm the system on condition that the zone is
defined as Force Arm enabled. This door must be closed by the end of the Exit delay otherwise an
alarm is generated. If the magnetic contact's zone is defined as Force Arm disabled, the system will
not be ready to arm until you close the door.
To program the Force Arm option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone's sub‐menu, select Force Arm [#07]; the zone's current Force Arm setting
is displayed.
4.
Select either Enabled or Disabled.
For the Force Arm feature to function, you must also enable Force Arming in System
Options ‐‐ see p. 53, 9.2.1 Forced Arm.