For  this  feature  to  function,  Trouble  Tones  must  be  enabled  in  programming  –  see  p.  51, 
8.6.1 System Trouble Tones.  
System  trouble  tones  are  not  sounded  from  10:00pm  to  7:00am  so  as  not  to  disturb  household 
members  who  may  be  asleep.  However,  you  can  program  the  system  to  immediately  annunciate 
telephone trouble at all times – see p. 51 8.6.2 Telephone Trouble Tones. 
3.5.2.

Vocal Message Annunciation

Certain versions of the CommPact Control System hardware support vocal annunciation of system 
status. If this feature is enabled in programming (see p. 59, 9.10 Vocal Messages), the system plays 
short  messages  to  indicate  arming,  disarming,  bypassed  zones,  system  trouble,  message  waiting, 
and water alarm. 
The availability of the Vocal Message annunciation feature is hardware dependent.  
3.5.3.

Alarm Sounding Patterns

The following table summarizes the system's various alarm patterns. 
Table 3-7: Alarm Patterns
Alarm
Burglary
Fire
Gas
Medical
Flood/
Environmental
3.6.

Arming and Disarming

The  following  section  explains  how  to  arm  and  disarm  the  Control  System  using  the  front  panel 
keypad or Wireless Keypad:  
3.6.1.
Arming
You  have  three  arming  modes  available:  full,  part,  and  perimeter.  Figure  3‐4  illustrates  the  three 
arming modes. In each diagram, the protected area is shaded. 
Full Armed
Figure 3-4: Arming Modes
The  arming  options  are  entirely  flexible.  You  can  program  each  detector  to  be  included  in  any 
combination of the three arming modes – see p. 42, 7.3.2 Arm Set. Additionally, each arming mode 
has a separate exit and entry delay.  
CommPact Installation Manual
Alarm Pattern Description
ON (continuously)
ON - ON - ON, 1.5-second pause, ON - ON – ON...
ON - ON - ON - ON (short bursts), 5 second pauses, ON - ON - ON -
ON...
ON (continuously) – only applicable for Medical alarm from zone
4 rapid tones sounded once per minute (same as Trouble tones)
Part Armed
Sounding
Device
Siren
Siren
Siren
Siren
Buzzer
Perimeter Armed