Carbon Monoxide Detector (El-2764) - Electronics Line CommPact Installation Manual

Hide thumbs Also See for CommPact:
Table of Contents

Advertisement

Actions to Take after the Problem is Corrected
Once  the  problem  about  the  gas  presence  in  the  premises  has  been  corrected,  the  alarm  of  the 
detector should be off. After waiting for 10 minutes, push the Test button to test the detector so that 
you can make sure that the detector is working properly again. 

Carbon Monoxide Detector (EL-2764)

The  EL‐2764  is  a  Wireless  Carbon  Monoxide  Detector  (CO)  that  detects  the  buildup  of  Carbon 
Monoxide. Upon detecting the CO gas, the unit emits an alarm and notifies the control panel. 
The main features of your CO gas detector include the following: 
Integrated transmitter designed for use with ELʹs wireless alarm systems 
  E asy to install 
Monitoring of carbon monoxide in a continuous manner 
Loud alarm (85 dB) when detecting a buildup of carbon monoxide 
Test button  
Continuous Self‐testing function 
What You Should Know About Carbon Monoxide
Carbon  monoxide,  also  known  as  ʺCOʺ  by  the  chemical  form,  is  considered  to  be  a  highly 
dangerous  poisonous  gas,  because  it  is  colorless,  odorless,  tasteless  and  very  toxic.  In  general, 
biochemistry phenomena have shown that the presence of CO gas inhibits the bloodʹs capacity to 
transport oxygen throughout the body, which can eventually lead to brain damage. 
In any closed space (home, office, recreational vehicle or boat) even a small accumulation of CO gas 
can be quite dangerous. 
Although many products of combustion can cause discomfort and adverse health effects, it is CO 
gas which presents the greatest threat to life. 
Carbon monoxide is produced by the incomplete combustion of fuels such as natural gas, propane, 
heating  oil,  kerosene,  coal,  charcoal,  gasoline,  or  wood.  The  incomplete  combustion  of  fuel  can 
occur in any device which depends on burning for energy or heat such as furnaces, boilers, room 
heaters,  hot  water  heaters,  stoves,  grills,  and  in  any  gasoline  powered  vehicle  or  engine  (e.g. 
generator set, lawnmower). Tobacco smoke also adds CO to the air you breathe. 
When  properly  installed  and  maintained,  your  natural  gas  furnace  and  hot  water  heater  do  not 
pollute  your  air  space  with  CO.  Natural  gas  is  known  as  a  ʺclean  burningʺ  fuel  because  under 
correct operating conditions, the combustion products are water vapor and carbon dioxide (CO2), 
which is not toxic. The products of combustion are exhausted from furnaces and water heaters to 
the outside by means of a fuel duct or chimney. 
Correct operation of any burning equipment requires two key conditions: 
  A n adequate supply of air for complete combustion 
Proper venting of the products of combustion from the furnace through the chimney, 
vent or duct to the outside 
126
Appendix B: Transmitter Installation
CommPact Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CommPact and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF