9.
System Options
As the name suggests, System Options are settings that affect the entire system. This chapter offers
explanations and programming instructions for each of these options.
9.1.
Code Lockout
The Code Lockout option locks the keypad for 30 minutes if five unsuccessful attempts are made to
enter the user code.
To program the Code Lockout setting:
1.
From the Programming menu, select System Options, Code Lockout [9401].
2.
Select Enabled or Disabled.
During the 30‐minute lockout period, you can still arm and disarm the system using
keyfobs. If one key arming is enabled, you may still arm the system using the keypads.
9.2.
Arm/Disarm Options
The options offered in this section relate to arming and disarming the system.
9.2.1.
Forced Arm
Forced arming enables you to arm the system when the system is not ready. This option allows you
to enable or disable Forced arming for the entire system. Additionally, you can enable or disable
Forced arming for each individual zone. For further information, see p. 43, 7.3.6 Force Arm.
To program the Forced Arm setting:
1.
From the Programming menu, select System Options, Arm/Disarm, Forced Arm [94021].
2.
Select Enabled or Disabled.
9.2.2.
One-Key Arming
You can arm the system by pressing any of the three arming keys on the keypad. If One‐Key
Arming is enabled, the system does not prompt you for a user code.
To program the One‐Key Arming setting:
1.
From the Programming menu, select System Options, Arm/Disarm, and One‐Key
Arming [94022].
2.
Select Enabled or Disabled.
9.2.3.
Supervised Arm
The Supervised Arm option is a feature designed to supervise a wireless device activity before you
arm the system. If the system has not received a transmission from a detector during the interval
defined for this option, all arming methods that include that detector will not be available. Medical,
Panic, Fire, Gas, Flood, and Environmental zones are not included in this supervision and do not
affect the system's ability to arm.
Press to check which detector is causing the ʺSystem Not Readyʺ condition.
To make the required arming method available, activate the detector. PIR detectors have a three‐
minute delay between transmissions.
CommPact Installation Manual
53