9.

System Options

As the name suggests, System Options are settings that affect the entire system. This chapter offers 
explanations and programming instructions for each of these options. 
9.1.

Code Lockout

The Code Lockout option locks the keypad for 30 minutes if five unsuccessful attempts are made to 
enter the user code. 
To program the Code Lockout setting: 
1.
From the Programming menu, select System Options, Code Lockout [9401]. 
2.
Select Enabled or Disabled. 
During the 30‐minute lockout period, you can still arm and disarm the system using 
keyfobs. If one key arming is enabled, you may still arm the system using the keypads. 
9.2.

Arm/Disarm Options

The options offered in this section relate to arming and disarming the system.  
9.2.1.
Forced Arm
Forced arming enables you to arm the system when the system is not ready. This option allows you 
to  enable  or  disable  Forced  arming  for  the  entire  system.  Additionally,  you  can  enable  or  disable 
Forced arming for each individual zone. For further information, see p. 43, 7.3.6 Force Arm. 
To program the Forced Arm setting: 
1.
From the Programming menu, select System Options, Arm/Disarm, Forced Arm [94021]. 
2.
Select Enabled or Disabled. 
9.2.2.
One-Key Arming
You  can  arm  the  system  by  pressing  any  of  the  three  arming  keys  on  the  keypad.  If  One‐Key 
Arming is enabled, the system does not prompt you for a user code. 
To program the One‐Key Arming setting: 
1.
From the Programming menu, select System Options, Arm/Disarm, and One‐Key 
Arming [94022]. 
2.
Select Enabled or Disabled. 
9.2.3.
Supervised Arm
The Supervised Arm option is a feature designed to supervise a wireless device activity before you 
arm the system.  If  the  system  has  not received a transmission from a detector during the interval 
defined for this option, all arming methods that include that detector will not be available. Medical, 
Panic, Fire,  Gas,  Flood, and  Environmental  zones  are not  included in  this supervision and do  not 
affect the system's ability to arm.  
Press  to check which detector is causing the ʺSystem Not Readyʺ condition.  
To  make  the  required  arming  method  available,  activate  the  detector.  PIR  detectors  have  a  three‐
minute delay between transmissions. 