logging level
This command sets the minimum severity level for event logging.
Syntax
logging level <Emergency | Alert | Critical | Error | Warning | Notice | Informational |
Debug>
Default Setting
Informational
Command Mode
Global Configuration
Command Usage
Messages sent include the selected level down to the Emergency level.
Level Argument
Emergency
Alert
Critical
Error
Warning
Notice
Informational
Debug
logging console
This command initiates logging of error messages to the console. Use the no form to disable logging
to the console.
Syntax
logging console
no logging console
Default Setting
Disabled
Command Mode
Global Configuration
logging host
This command specifies a syslog server host that will receive logging messages. Use the no form to
remove syslog server host.
December 2006
Description
System unusable
Immediate action needed
Critical conditions (e.g., memory allocation, or free memory error -
resource exhausted)
Error conditions (e.g., invalid input, default used)
Warning conditions (e.g., return false, unexpected return)
Normal but significant condition, such as cold start
Informational messages only
Debugging messages